Human Health Care Service 밝은 웃음과 행복한 가족, 사회를 이루어 가겠습니다.

퀵메뉴

상담전화 제품구매 033 434-9041~2 고객상담 033 434-9041~2

> Product > PRODUCT GROUP1

BPM-1010(MATRON)

Multi Parameter Patient Monitor

Experience the superiority of high-performance monitor, Patron You can get more and better than anything you have ever tasted before.

∴ Details

  • • 10.4” Large touchable LCD display of 800x600
    • Configurable up to 12 waveforms
    • 3ch ECG(12ch EKG option) Resp, NIBP, SpO2, 2IBP(4IBP option) 2Temp(4Temp option) EtCo2(Main stream/Side Stream) option
    Optional Cardlac output, Optional Multi Gas (CO2, N2O)
    • 13 kinds Of Arrhythmia Detect
    • 1200 of ECG Recall for 20seconds
    • Unlimited configurations and flexible parameter position at user's command
    • 30 days of graphic and list trends(mini trend screen)
    • 120 episodes of alarm event recall for 20 seconds event data & graphic, which can be zoomed to observe and to print out
    • Easy to upgrade Software by SD Card (Max. 16G)
    • 2 rechargeable Li-ion batteries offer up to 5 hours of operation time
    • RS-232C interface, VGA Out, Nurse call port
    • EMR, HL7, Wired & Wireless Central Station

    ■Display
    •Screen : 10.4” color TFT LCD
    •Resolution : 800(H) X 600(V) SVGA
    •Trace line : 6 waveform (Std.) / 12 waveform max (Opt.)
    Up to wave trace on/off
    (3ch ECG(Std.), 12ch EKG(Opt.) SpO2, 4IBP, RESP, EtCO2, Multi Gas)
    ■Parameters
    •Display : ECG, SpO2, NBP, 4IBP, RESP, 4TEMP, EtCO2, Multi Gas, ICO, HRV,
    OXY-CRG, APG detect analysis, ST level display, mini trend, ECG Recall,
    Drug Dose, Color change, Temp TD, NIBP Text trend.
    ●ECG
    •Channel : 3 channels (Std.) / 12 channels EKG(Opt.)
    •Electrode : 3 or 5 electrode (10 electrode (Opt.)
    •3 lead wire : I, II, III (1 lead at a time)
    •4 lead wire : I, II, III, aVR, aVL, aVF (Up to 6leads at a time)
    •5 lead wire : I, II, III, aVR, aVL, aVF, V (Up to 7leads at a time)
    •10 lead wire : I, II, III, aVR, aVL, aVF, V1, V2, V3, V4, V5, V6 (All 12-leads of ECG at a time)
    •Filter : High frequency noise remove filter (50/60Hz), Frequency Bandwidth (0.05~80Hz)
    •Gain : 2.5, 5, 10, 20, 30, 40, Auto mm/mV
    •Sweep Speed : 6.25, 12.5, 25, 50 mm/sec
    •Heart rate : 0 ~ 300 bpm, ±2bpm
    •Input signal range : 0±0.5mV ~ ±5mV
    •QRS Detect : 0.15mV ~ 0.40mV (Manual)
    •Defibrillator Protection : 300Joules delivered at 5000Volts
    •Defibrillation Artifact Recovery Time : <8s
    •Pacemaker Detection Mode : User selectable (PNF, PNC)
    •Arrhythmia Detect(13Detect) : TAC, BRD, PVC, VTAC, ASY, BGM, TGM, VENT, VFIB, CPT, TPT, MIB, Ront
    •ST Analysis : Rang : -9.9mm ~ +9.9mm / Resolution : 0.1mm (Lead : ECG Channel Selection same)
    •HR Calculation : 4~16 QRS wave
    ● Respiration
    •Method : Impedance for ECG Lead(selectable)
    •Respiration rate : 0 ~ 150 bpm
    •Accuracy : +/- 2% or +/- 2 bpm
    •Lead Selection : I, II
    •Apnea : OFF, 10 ~ 60sec
    •GAIN : X0.25, X0.5, X1, X2, X4, AUTO
    •SWEEP SPEED : 3.12, 6.25, 12.5, 25, 50mm/sec
    ● NIBP
    •Technique Pressure : Oscillometric
    •Measurement range : Adult : 0 ~ 300 mmHg
    Neonate : 0 ~ 150mmHg
    •NIBP VENOUS STAT : 50 ~ 200mmHg
    •Auto Measurement Cycle : 1 ~ 59 min, 1 ~ 12 hr
    •STAT mode : 5 ~ 15 min of consecutive
    •With an optional port : Suntech
    ●SpO2
    •Probe : Finger type reusable sensor
    •SpO2 Range : 0 ~ 100%
    •Pulse Rate : 0 ~ 300 bpm
    •Resolution : 1 %
    •GAIN : X0.25, X0.5, X1, X2, X4 AUTO
    •Sweep Speed : 6.25, 12.5, 25, 50 mm/sec
    •Setting Time : Wave out Time : Max 2 sec
    SpO2 Percentage Display : Max 10 sec
    •Low Perfusion Accuracy : 0.1% up to
    •SpO2 : ±2 %, for readings 70 ~ 100 %
    ±3 %, for readings 50 ~ 69 %
    Unspecified 0 ~ 49 %
    •Pulse : ±2bpm, for readings 0~240bpm
    ±3bpm, for readings 241 ~ 300bpm
    •Setting Time wave out time : 5 sec max (Based on 75bpm)
    •With an optional port : Nellcor OXI-MAX
    ● IBP
    •Channel : 2(Standard), 4(Option)
    •Measurement range : -50 ~ 400 mmHg
    •Catheter : Yuta, Biosensors International
    •Accuracy : ±1 %
    •Zero balance : ±150 mmHg
    •MODE : ABP, FEM, PA, CVP, LA, RA, ICP, SP
    •Sweep Speed : 6.25, 12.5, 25, 50mm/sec
    ●Temperature
    •Channel : 2(Standard), 4(Option)
    •Type : YSI – 400 Serise
    •Measurement range : 0 ~ 50.0 ℃
    •Accuracy : ±0.1℃, for readings 25.0 ~ 50.0℃
    ±0.2℃, for readings 0 ~ 24.9℃
    •Temp TD : Support
    ●EtCO2 (Optional)
    •Measurement Mode : Respironics Mainstream/Sidestream
    Phasein Mainstream/Sidestream
    •Measurement range : 0~150mmHg (kPa / %)
    •Accuracy : 0-40 mmHg ± 2mmHg
    41-70 mmHg ± 5mmHg
    71-150 mmHg ± 10mmHg
    •GAIN : X0.25, X0.5, X1, X2, X4, AUTO
    •Sweep Speed : 3.12, 6.25, 12.5, 25, 50mm/sec
    •Respiration rate : 0-150 bpm / Accuracy ± 2% or ± 2 bpm
    ● Cardiac Output (Optional)
    •Method : Thermodilution
    •Parameters : CI, SV, SI, LVSW, LVSWI, RVSW, VSWI, SVR, SVRI, PVR, PVRI
    •Catheter : Swan-Ganz standard Themodilution pulmonary
    Artery Catheter(131HF7, 744HF75)
    •Edward Lifesciences
    ● Multi Gas (Optional)
    •Parameters : CO2, N2O
    •Anesthetic Agent : Halothane, Enflurane, Isoflurane, Desflurane, Sevoflurane
    ● tPICCO Support (Optional)
    •Hemodynamic Extension includes cardiac output, continuous cardiac output using tPICCO technology,
    2 invasive blood pressure. An additional invasive blood pressure port is optional.
    ● Printer (Option)
    •Channel : 3
    •Paper size : 58 mm
    ■ECG Recall
    •Storage : Recall 20 seconds event data with graphic, and 2 seconds data can be
    zoomed to observe and analyze and Printed out.
    •Save up to data(1ch) : 1200
    ■Event Recall
    •Storage : Recall 20 seconds event data with graphic, and 2 seconds data can be
    zoomed to observe and analyze and Printed out.
    •Save up to data : 120
    ■Data Recall
    •Storage : full graphic and tabular trends of all parameters.
    •Save up to data : 720 hour
    ■Interface
    •Port : RS-232, VGA, LAN and Wireless LAN(Opt.), ECG Output: Signal(1mV)/
    Defibrillator sync out(5V, 100ms)(opt.), IBP Output: Signal(opt.),
    SD Memory Card Port, Nurse Call Port
    ■Language
    •Parameters : ENGLISH, FRENCH, SPANISH, GERMAN, ITALIAN, RUSSIAN, TURKISH,
    CZECH, RUMANIA, PORTUGAL (Can be applied to all languages.)
    ■Trend
    •Memory Storage : 30 days (Standard) All parameters
    43,400 sets(1set per minute) of virtual signs list data can be stored, reviewed, and Printed out.
    •Tabular and Graphic Data Interval : 1, 5, 15, 30 min ---and 1 Hours
    ■Battery
    •Internal Battery : Li-ion Battery (DC : 10.8V/2.6A _Std.) (10.8V/4.4A _Opt. )
    •Operating time : Min. up to 1hours (Std.) / Max. up to 5hours (2Pack – Opt.)
    ■Network : EMR, HL7, Central Monitoring(Bionics) / SD Card Patient information Save Data in review
    ■Physical Characteristics
    •Dimensions : W310 x D160 x H290mm •Weight : Weight 7Kg (Only Bady)
    ■Power requirements
    •Voltage input : 100-240V~, 50-60Hz •Power consumption : 120VA

∴ ACC